prostep IVIP
  • Suche
  • Drucken
  • LinkedIn
  • Xing
  • YouTube
  • Xing

CATIA V5 (Dassault) >> OneSpace Designer

The following settings are recommended up to CATIA V5R24 (V5-6R2014) (Dassault) and CoCreate Modeling 16.5.

CATIA V5 (Dassault) – System

  • Model should be cleaned of all unlinked information
  • Delete unused elements from the NOSHOW area.

CATIA V5 (Dassault) - STEP Preprocessor

  • Recommended settings in the STEP export options (Tools -> Options...-> Compatibility…-> STEP) :
  • Choose the respective Application Protocol (AP): AP203, AP242 or AP214 (recommended).
  • When exporting assemblies choose One Step File, because CC6 (External references) is not supported from all STEP processors.
  • Do not export the NO SHOW area (set Export all entities: off).
  • Optionally define the Header of STEP file.
  • Validation properties are supported.
  • If export a CATProduct:
  • The option "work with cache system" has to be switched off (Tools -> Options -> Infrastructure -> Cache Management)
  • The root node has to be selected, otherwise only the node of the CATPart will be exported

STEP File

  • An adjustment of the STEP file extension is not necessary.

OneSpace Designer - STEP Postprocessor

  • The properties for STEP import can be found in the file -> open -> options dialog
  • Set the accuracy to automatic (default) to use the accuracy of the STEP file.
  • If the accuracy is customized, make sure that the accuracy setting is the same or less than the accuracies setting used to generate the part being loaded.
  • When associated messages are returned during the import of the STEP file the accuracy should be adjusted.
  • If a product with multiple bodies is imported, Solid Designer creates an assembly.
  • Blended edges are not recognized as such, and it is not possible to modify blends using standard OneSpace Designer.
  • The import log file "step_load_log" gives further information.

OneSpace Designer – System

  • Shaded view is helpful and gives a first impression of the model quality.
  • To ensure the model quality is OK a complete model check should be performed.

back

Support

We are eager to help you with any questions concerning your project or selection of publications

Telefon
TELEPHONE HOTLINE
+49 6151 9287-336

Newsletter

Register for your individual news about prostep ivip.

Our Blog

Here you will find news about prostep ivip and all topics about digital transformation.

Blog

Read the latest topics

Follow us

For more inspiration, news and information about prostep ivip.

LinkedInXingYouTubeTwitter

ImprintPrivacy StatementLegal Notice