The following settings are recommended up to AutoCAD 2017/Mechanical Desktop 2017 and Solid Edge ST 8.

AutoCAD/MDT – System

  • Delete all non-referenced geometry.
  • Please activate all the layers with features to be exported.
  • Only standard colors are transferred. Sub-elements of objects cannot be colored individually in the systems.
  • Models are exported as an assembly.
  • Please execute "AMUPDATE" to update the model geometry.
  • Use AMREPLAY to regenerate the model step by step. This helps to identify corrupt features in the overall context of the design progress.
  • Use AMSANITYCHECK to count the numbers of shells within the model. Usually a MD model should contain only one shell. Exception: Intended voids.

AutoCAD/MDT - STEP Preprocessor

  • To export a STEP File you can choose File -> Export ->STEP or the STEPOUT in the command line.
  • The STEP standard can be chosen in the OPTIONs menu.
  • The translator uses a default file extension of *.stp when processing STEP file names entered on the command line.
  • The default setting for STEP export is AP214. 

STEP File

  • No adjustment is necessary.

Solid Edge - STEP Postprocessor  

  • To import a STEP file go to File -> Open, select the STEP file and go to Options. The Open File dialog box appears.
  • These are the recommended options that must be selected:
    • Generate Log File: to create a log file that contains warnings and information about the imported files. The name of the file is the <filename>.log and it is located in the same folder as the STEP file.
    • Heal and Stitch: to heal and stitch the free surfaces to create a solid body. It is not required to specify a tolerance range.
    • Simplify Geometry: replace the b-spline geometry from the model with simplified analytic geometry. This creates a smaller and more efficient model.
  • In case of an assembly it is recommended to select the same Output Folder as the one where the imported *.asm file is going to be saved, otherwise the imported *.par files will be saved in the same folder as the STEP file.
  • The New dialog box opens after choosing the STEP file. To import the model, a new part or assembly must be first created.

Solid Edge – System

  • In case of an assembly a *.cfg file is created. This one contains the Display Configurations of the model.

back

Support

We are eager to help you with any questions concerning your project or selection of publications

Telefon
TELEPHONE HOTLINE
+49 6151 9287-336

Newsletter

Register for your individual news about prostep ivip.

Our Blog

Here you will find news about prostep ivip and all topics about digital transformation.

Blog

Read the latest topics

Follow us

For more inspiration, news and information about prostep ivip.

LinkedInXingYouTubeTwitter

ImprintPrivacy StatementLegal Notice